Probes

OPHIREMC series of current and injection probes are designed for testing to various EMC standards such as Mil-Std- 461G, RTCA DO-160G, CISPR, Automotive and others. Current Probes cover frequency range from 20 Hz to 1 GHz. Injection Probes frequency range coverage is 10 kHz to 1 GHz. Calibration Fixtures for probes are available.

Current and Injection Probes

Current and Injection Probes

OPHIREMC series of current and injection probes are designed for testing to various EMC standards such as Mil-Std-461, RTCA-DO-160, CISPR, Automotive, and others.

Current Probes Specifications

Part No Freq. Zt Max. A 400Hz Max. CW Max. Pulse Window
OCP216 20Hz-20MHz 0.03 400 220 5000 1.25
OCP218 10kHz-500MHz 1-5 200 40 60 1.25
OCP219 10kHz-150MHz 1 350 4.2 100 1.25
OPC405 10kHz-400MHz 6 4 15 2.00
OCP321 100kHz-500MHz 8 200 25 50 2.62
OCP324 10kHz-300MHz 8 300 62 62 2.62

Bulk Current Injection Probes Specifications

Part No Frequency Wind A Watts Window
OIP251 5MHz-1GHz 50 1.25
OIP400 10kHz-400MHz 100 2

Calibration Fixtures

Part No Frequency Width Height Center
OFC120 20Hz-500MHz 10 7 6
OFC121 100kHz-1GHz 10 7 7
OFC403 10kHz-400MHz 6 6.5 6.5